Home
Contact us
Links
Crouzet-usa.com
 C-Lynx  Applications  Selection guide  FAQ  Crouzet network
  Home > Selection guide > Phase control
 
Phase control
 
     
               
MWS 84873020 Phase failure and phase sequence  - 208-480 V AC 50/60 Hz Self-powered 208-480 V AC   1 single changeover relay 5 A
MWS2 84873021 Phase failure and phase sequence - 208-480 V AC 50/60 Hz Self-powered 208-440 V AC   2 single changeover relay 5 A
MWG 84873022 Phase failure and phase sequence Regeneration 70% of Un 208-480 V AC 50/60 Hz Self-powered 208-480 V AC   1 single changeover relay 5 A
MWU 84873023 Phase failure and phase sequence Regeneration 70% of Un 208-480 V AC 50/60 Hz Self-powered 208-480 V AC 0.1s
to 10s
1 single changeover relay 5 A
Undervoltage Phase/phase Un:
208/220/380/400/415/440/480 V AC
-20% to -2%
MWA 84873024 Phase failure and phase sequence Regeneration 70% of Un 208-480 V AC 50/60 Hz Self-powered 208-480 V AC 0.1s
to 10s
1 single changeover relay 5 A
Asymmetry - 5% to 15%
MWUA 84873025 Overvoltage/undervoltage
(window)
Phase/phase Un:
208/220/380/400/415/440/480 V AC
-20% to -2% +2%
to +20%
Self-powered 208-480 V AC 0.1s
to 10s
1 single changeover relay 5 A
Asymmetry - 5% to 15%
Phase failure and phase sequence - 208-480 V AC 50/60 Hz
HWUA 84873026 Overvoltage

Asymmetry
Phase/phase Un:
220/380/400/415/440/480 V AC
-
+2% to +20%

5% to 15%
Self-powered 220-480 V AC 0.1s
to 10s
1 double changeover relay
2 X 5 A
Undervoltage

Phase failure and phase sequence
Phase/phase Un:
220/380/400/415/440/480 V AC
-
-20% to -2%

220-480 V AC 50/60 Hz
H3US 84873220 Phase failure - 220-480 V AC 50/60 Hz Self-powered 220-480 V AC 0.3s
to 30s
2 single changeover relay 5 A
Undervoltage Phase/phase Un:
220/380/400/415/440/480 V AC
-20% to -2%
Overvoltage Phase/phase Un:
220/380/400/415/440/480 V AC
+2% to +20%
H3USN 84873221 Loss of phase
and neutral
- 120-277 V AC 50/60 Hz Self-powered 120-277 V AC 0.3s
to 30s
2 single changeover relay 5 A
Undervoltage Phase/neutral Un:
120/127/220/230/240/260/277 V AC
-20% to -2%
Overvoltage Phase/neutral Un:
120/127/220/230/240/260/277 V AC
+2% to +20%
M3US 84873222 Phase failures
- 208-480 V AC 50/60 Hz Self-powered 208-480 V AC 0.3s
to 30s
1 single changeover relay 5 A
Undervoltage Phase/neutral Un:
208/220/380/400/415/440/480 V AC
-20% to -2%
Overvoltage Phase/neutral Un:
208/220/380/400/415/440/480 V AC
+2% to +20%
   
 Selection guide

Search our Site

Check Distributor Stock
Enter Part No:

Powered by Mectronic.net
Consult our eCatalog
Download the C-Lynx documentation
© 2005 Crouzet Automatismes SAS